DisableDeviceWithTimeOut

Definition

Usage

Disable the device for a period of time.

Parameter

Device number

Duration of disabling the device

Return Value

Return True if it is successful, or return False.

EnableDevice

None

 

Ejemplo

C#

        /// <summary>
        /// Set the time length that the device will be Unavailable
        /// Here we set the device to be Unavailable for 5 seconds.
        /// </summary>
        /// <param name="IP"> Ip of device </param>
        /// <param name="Port"> Port of Device </param>
        /// <param name="MachineNumber"> Device Number </param>
        private void DisableDeviceWithTimeOut(string IP = "10.0.0.44", int Port = 4370, int MachineNumber = 1)
        {
        //Create Standalone SDK class dynamicly.
            zkemkeeper.CZKEMClass axCZKEM1 = new zkemkeeper.CZKEMClass();
            axCZKEM1.Connect_Net(IP, Port);
        int idwErrorCode = 0;
        if (axCZKEM1.DisableDeviceWithTimeOut(MachineNumber, 5))
            {
                axCZKEM1.RefreshData(MachineNumber); //the data in the device should be refreshed
                MessageBox.Show("The device will under working state for 5 seconds!", "Success");
            }
        else
            {
                axCZKEM1.GetLastError(ref idwErrorCode);
                MessageBox.Show("Operation failed,ErrorCode=" + idwErrorCode.ToString(), "Error");
            }
        }

VB

        ''' <summary>
        ''' Set the time length that the device will be Unavailable. Here we set the device to be Unavailable for 5 seconds.
        ''' </summary>
        ''' <param name="IP"> Ip of device </param>
        ''' <param name="Port"> Port of Device </param>
        ''' <param name="MachineNumber"> Device Number </param>
        Private Sub DisableDeviceWithTimeOut(Optional IP As String = "10.0.0.44", Optional Port As Integer = 4370, Optional MachineNumber As Integer = 1)
        Dim idwErrorCode As Integer = 0
        'Create Standalone SDK class dynamicly.
        Dim axCZKEM1 As New zkemkeeper.CZKEM
        axCZKEM1.Connect_Net(IP, Convert.ToInt32(Port))
        If axCZKEM1.DisableDeviceWithTimeOut(MachineNumber, 5) = True Then
            axCZKEM1.RefreshData(MachineNumber) 'the data in the device should be refreshed
            MsgBox("The device will under working state for 5 seconds!", MsgBoxStyle.Information, "Success")
        Else
            axCZKEM1.GetLastError(idwErrorCode)
            MsgBox("Operation failed,ErrorCode=" & idwErrorCode.ToString(), MsgBoxStyle.Exclamation, "Error")
        End If
        End Sub